facebook pinterest linkedin twitter youtube
Home Membrane Electrolysis Technology Hypochlorous Acid Generator

Acidic Electrolyzed Oxidizing Water Ionizer For Hospital

Acidic Electrolyzed Oxidizing Water Ionizer For Hospital

Acidic Electrolyzed Oxidizing Water, another name “Hypochlorous acid” is a neutral, low-molecular-weight small molecule with no charge, allowing it to easily penetrate the negatively charged cell membranes and efficiently disrupt functional enzymes inside bacteria. Its bactericidal effectiveness is approximately 100 times greater than that of alcohol or iodine-based disinfectants. It can rapidly eliminate a wide range of microbial pathogens within a short period. Even highly resilient spore-forming bacteria can be killed within 10 minutes, achieving a destruction rate of over 99% against bacteria, fungi, and viruses.

  • Model:

    PAE-10
  • HOCl Output:

    ≥1L/min
  • HOCl concentration:

    40~200ppm
  • PH range:

    5.0~6.5
  • ORP range:

    800~1000mv
  • Cell type:

    Membrane Cell
  • Rate power:

    220V AC 50HZ
  • Additive:

    Salt
  • Control mode:

    Auto Control
  • Product Details

Acidic Electrolyzed Oxidizing Water Ionizer For Hospital

Principle of electrolysis

By adding low-concentration sodium chloride to softened water and conducting an electrochemical reaction through electrolysis in a diaphragm electrolyzer, an acidic aqueous solution with hypochlorous acid as the primary bactericidal component is generated.

 

Using only salt and water as raw materials, the anode chamber produce strongly acidic electrolyzed water, while the cathode chamber produce strongly alkaline electrolyzed water. When weakly acidic electrolyzed water is required, the strongly acidic and strongly alkaline solutions are mixed to adjust the pH to the appropriate level. Any excess strongly alkaline electrolyzed water is discharged.
 

 

 

 

 

 


Application For Hospital

Sterilization of Surgical Instruments and Items Cleaned Manually Prior to Sterilization

After manual cleaning according to WS 3102, flush and soak for disinfection with flowing electrolyzed oxidizing water for 2 minutes. Rinse with purified water for 30 seconds, then remove and air-dry or wipe dry with a sterile cloth before proceeding with sterilization as required.

 

Disinfection of Endoscopes

After pre-processing, leak testing, cleaning, and rinsing of the endoscope according to WS 507 requirements, completely submerge it in electrolyzed oxidizing water. Connect the outlet of the electrolyzed oxidizing water to all channels of the endoscope using a full-channel irrigator, and use a power pump to fill all channels with the disinfectant. Flush and soak for disinfection for 3 to 5 minutes, then perform terminal rinsing and drying according to WS 507 requirements.

 

Disinfection of General Medical Devices

After thorough cleaning of general medical devices, flush and soak them in flowing electrolyzed oxidizing water for 3 to 5 minutes.

 

 

 

 

 

Hygienic Disinfection

When using electrolyzed oxidizing water for disinfection, first rinse with alkaline electrolyzed water for 20 seconds, then flush and disinfect with flowing electrolyzed oxidizing water for 1 minute, followed by a final rinse with alkaline electrolyzed water or tap water for 10 seconds. When using slightly acidic electrolyzed water for disinfection, flush and disinfect for 1 minute, then rinse with tap water for 10 seconds. If hands are heavily soiled, they should be thoroughly cleaned before proceeding with the disinfection process as described.

Skin and Mucous Membrane Disinfection

Rinse or repeatedly scrub the area with electrolyzed oxidizing water or slightly acidic electrolyzed water for 3 to 5 minutes for disinfection.

Disinfection of Dental Unit Waterlines (Note: Not covered in our instruction manual)

For initial disinfection, use 40 mg/L slightly acidic electrolyzed water to flush and disinfect the tubing until the water quality at all outlets meets the GB 5749 standard requirement of ≤100 CFU/mL for total bacterial count. For daily maintenance, use 10 mg/L slightly acidic electrolyzed water for routine sanitation of the tubing and for mouth rinsing.

 

 

 

  • #
    Disinfection of gastrointestinal endoscopes
    Disinfectants used in endoscope cleaning and disinfection primarily include ortho-phthalaldehyde, glutaraldehyde, peracetic acid, chlorine dioxide, and electrolyzed oxidizing water.
     
  • #
    Disinfection of skin and mucous membranes
    Disinfection between continuous treatments and procedures
  • #
    Disinfection of Dental Unit Waterlines
    Multiple cities have mandated periodic disinfection of dental unit waterlines. Disinfectants may include hypochlorous acid solutions characterized by low toxicity, minimal odor, easy degradability, and no significant impact on the sensory properties of water.
  •  

--------------占位---------------

 

 

 


 

Specifications

 

Model PAE-10
Dimension of Host Machine 650*600*1770mm
PH of Slightly acidic water 5.0-6.5
Free Chlorine Concentration 40~200 mg/L
Output ≥1L/min
Power 220V AC 50hz
Inlet water requirement Tap Water (included softener)
Storage Tank External storage tank
Control Mode PLC control
Remote Control mobile/computer remote control
Installation Environmental ventilation good

 




 

 

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

500ppm Hypochlorous Acid generator
500ppm 5~6.5 PH 1 Year Shelf-life Hypochlorous Acidic Generator

Hypochlorous acid generator is a system which is produced by electrolysis of tap water through water purification system and is produced by a special electrolytic cell. The system produce hypochlorous acid (HCLO) with pH (5~6.5), redox potential (ORP value +750mv or more) and available chlorine (50~60mg/L), also produce sodium hydroxide (NaOH) with PH (10~12), redox potential(ORP value -800~900 mv).

View More
Natural  Hypochlorous Acid Generator
800ppm Natural Hypochlorous Acid Generator for Air Disinfection

Hypochlorous acid generator is a system which is produced by electrolysis of tap water through water purification system and is produced by a special electrolytic cell. The system produce hypochlorous acid (HCLO) with pH (5~6.5), redox potential (ORP value +750mv or more) and available chlorine (50~60mg/L), also produce sodium hydroxide (NaOH) with PH (10~12), redox potential(ORP value -800~900 mv).

View More
Hypochlorous Acid Generator
1000ppm PH7 Hypochlorous Acid Generator for Production Line

Hypochlorous acid generator is a system which is produced by electrolysis of tap water through water purification system and is produced by a special electrolytic cell. The system produce hypochlorous acid (HOCl) with pH (5~6.5), redox potential (ORP value +750mv or more) and available chlorine (50~60mg/L), also produce sodium hydroxide (NaOH) with PH (10~12), redox potential(ORP value -800~900 mv).

View More
Sodium Hypochlorite Generator
Sea Water Electrolysis Sodium Hypochlorite Generator for Cooling Tower

Sea Water Electrolysis Sodium Hypochlorite Generator is used electrolytic principle, it works through by on-site electrolysis of seawater to produce sodium hypochlorite solution, and automatically dosing into the feed seawater to eliminate algae and microorganisms, thus prevent the biofouling in the seawater system (such as cooling circuits, intake pipes and heat exchangers). 

View More
Platinum Dimensionally Stable Anode
Platinum coating Pure Titanium Dimensionally Stable Anode

Platinum-coated titanium electrode is a typical Dimensionally Stable Anode. It is a composite electrode constructed with a metallic titanium substrate as the base, upon which a thin layer of platinum (often not pure platinum but rather an alloy or mixture of platinum and other precious metals) serving as the active catalytic layer is applied onto its surface through specialized processes such as thermal decomposition or electroplating.

View More
Electro chlorination System
Sea Water Electro Chlorination System for Power Plant Cooling System

Sea Water Electro Chlorination System is used electrolytic principle, it works through by on-site electrolysis of seawater to produce sodium hypochlorite solution, and automatically dosing into the feed seawater to eliminate algae and microorganisms, thus prevent the biofouling in the seawater system (such as cooling circuits, intake pipes and heat exchangers). 

View More
Sodium Hypochlorite Dosing System
Jesco Pump Sodium Hypochlorite Chemical Dosing System for Water Plant

The sodium hypochlorite dosing system is configured with a softened water dilution function todilute the storage concentration of sodium hypochlorite to less than 5%

View More
Salt Water Sodium Hypochlorite Generator
200g/h Split Type Salt Water Electrolysis Sodium Hypochlorite Generator for Small Drinking Water Plant

The Esegen sodium hypochlorite generator generates a 0.8 % sodium hypochlorite solution through the electrolysis of brine, consuming only water, salt and electricity. By producing hypochlorite on-site and on-demand, the system eliminates concerns associated with transportation and storage of chlorine gas or commercial sodium hypochlorite solutions, making it ideal for any medium to large scale application requiring chlorination.

View More
  Esegen (Guangzhou) Technology Co., Ltd is a technology-driven enterprise specializing in environmental protection equipment R&D. Our company is headquartered in Germany, we are dedicated to serving the global water treatment market.. With decades of expertise in catalytic oxidation, electrolysis, disinfection, and the R&D, design, and manufacturing environmental protection equipment, we are one of the most experienced companies in this field and recognized as a High-Tech Enterpris...
Room 814, Building 8, No. 80, Shilian Road (Shiqi Village Section), Shiqi Town, Panyu District, Guangzhou, China
Subscribe to Our Newsletter
Please Read On, Stay Posted, Subscribe, And We Welcome You To Tell Us What You Think.
SIGN UP
Follow Us
facebook pinterest linkedin twitter youtube

Copyright @ Esegen (Guangzhou) Technology Co., Ltd All Rights Reserved. Network Supported

XML Privacy Policy

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

WhatsApp

contact