Acidic Electrolyzed Oxidizing Water, another name “Hypochlorous acid” is a neutral, low-molecular-weight small molecule with no charge, allowing it to easily penetrate the negatively charged cell membranes and efficiently disrupt functional enzymes inside bacteria. Its bactericidal effectiveness is approximately 100 times greater than that of alcohol or iodine-based disinfectants. It can rapidly eliminate a wide range of microbial pathogens within a short period. Even highly resilient spore-forming bacteria can be killed within 10 minutes, achieving a destruction rate of over 99% against bacteria, fungi, and viruses.

  • Model:

    PAE-10
  • HOCl Output:

    ≥1L/min
  • HOCl concentration:

    40~200ppm
  • PH range:

    5.0~6.5
  • ORP range:

    800~1000mv
  • Cell type:

    Membrane Cell
  • Rate power:

    220V AC 50HZ
  • Additive:

    Salt
  • Control mode:

    Auto Control
  • Product Details

Acidic Electrolyzed Oxidizing Water Ionizer For Hospital

Principle of electrolysis

By adding low-concentration sodium chloride to softened water and conducting an electrochemical reaction through electrolysis in a diaphragm electrolyzer, an acidic aqueous solution with hypochlorous acid as the primary bactericidal component is generated.

 

Using only salt and water as raw materials, the anode chamber produce strongly acidic electrolyzed water, while the cathode chamber produce strongly alkaline electrolyzed water. When weakly acidic electrolyzed water is required, the strongly acidic and strongly alkaline solutions are mixed to adjust the pH to the appropriate level. Any excess strongly alkaline electrolyzed water is discharged.
 

 

 

 

 

 


Application For Hospital

Sterilization of Surgical Instruments and Items Cleaned Manually Prior to Sterilization

After manual cleaning according to WS 3102, flush and soak for disinfection with flowing electrolyzed oxidizing water for 2 minutes. Rinse with purified water for 30 seconds, then remove and air-dry or wipe dry with a sterile cloth before proceeding with sterilization as required.

 

Disinfection of Endoscopes

After pre-processing, leak testing, cleaning, and rinsing of the endoscope according to WS 507 requirements, completely submerge it in electrolyzed oxidizing water. Connect the outlet of the electrolyzed oxidizing water to all channels of the endoscope using a full-channel irrigator, and use a power pump to fill all channels with the disinfectant. Flush and soak for disinfection for 3 to 5 minutes, then perform terminal rinsing and drying according to WS 507 requirements.

 

Disinfection of General Medical Devices

After thorough cleaning of general medical devices, flush and soak them in flowing electrolyzed oxidizing water for 3 to 5 minutes.

 

 

 

 

 

Hygienic Disinfection

When using electrolyzed oxidizing water for disinfection, first rinse with alkaline electrolyzed water for 20 seconds, then flush and disinfect with flowing electrolyzed oxidizing water for 1 minute, followed by a final rinse with alkaline electrolyzed water or tap water for 10 seconds. When using slightly acidic electrolyzed water for disinfection, flush and disinfect for 1 minute, then rinse with tap water for 10 seconds. If hands are heavily soiled, they should be thoroughly cleaned before proceeding with the disinfection process as described.

Skin and Mucous Membrane Disinfection

Rinse or repeatedly scrub the area with electrolyzed oxidizing water or slightly acidic electrolyzed water for 3 to 5 minutes for disinfection.

Disinfection of Dental Unit Waterlines (Note: Not covered in our instruction manual)

For initial disinfection, use 40 mg/L slightly acidic electrolyzed water to flush and disinfect the tubing until the water quality at all outlets meets the GB 5749 standard requirement of ≤100 CFU/mL for total bacterial count. For daily maintenance, use 10 mg/L slightly acidic electrolyzed water for routine sanitation of the tubing and for mouth rinsing.

 

 

 

  • #
    Disinfection of gastrointestinal endoscopes
    Disinfectants used in endoscope cleaning and disinfection primarily include ortho-phthalaldehyde, glutaraldehyde, peracetic acid, chlorine dioxide, and electrolyzed oxidizing water.
     
  • #
    Disinfection of skin and mucous membranes
    Disinfection between continuous treatments and procedures
  • #
    Disinfection of Dental Unit Waterlines
    Multiple cities have mandated periodic disinfection of dental unit waterlines. Disinfectants may include hypochlorous acid solutions characterized by low toxicity, minimal odor, easy degradability, and no significant impact on the sensory properties of water.
  •  

--------------占位---------------

 

 

 


 

Specifications

 

Model PAE-10
Dimension of Host Machine 650*600*1770mm
PH of Slightly acidic water 5.0-6.5
Free Chlorine Concentration 40~200 mg/L
Output ≥1L/min
Power 220V AC 50hz
Inlet water requirement Tap Water (included softener)
Storage Tank External storage tank
Control Mode PLC control
Remote Control mobile/computer remote control
Installation Environmental ventilation good

 




 

 

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

500ppm Hypochlorous Acid generator
500ppm 5~6.5 PH 1 Year Shelf-life Hypochlorous Acidic Generator

Hypochlorous acid generator is a system which is produced by electrolysis of tap water through water purification system and is produced by a special electrolytic cell. The system produce hypochlorous acid (HCLO) with pH (5~6.5), redox potential (ORP value +750mv or more) and available chlorine (50~60mg/L), also produce sodium hydroxide (NaOH) with PH (10~12), redox potential(ORP value -800~900 mv).

View More
Natural  Hypochlorous Acid Generator
800ppm Natural Hypochlorous Acid Generator for Air Disinfection

Hypochlorous acid generator is a system which is produced by electrolysis of tap water through water purification system and is produced by a special electrolytic cell. The system produce hypochlorous acid (HCLO) with pH (5~6.5), redox potential (ORP value +750mv or more) and available chlorine (50~60mg/L), also produce sodium hydroxide (NaOH) with PH (10~12), redox potential(ORP value -800~900 mv).

View More
Hypochlorous Acid Generator
1000ppm PH7 Hypochlorous Acid Generator for Production Line

Hypochlorous acid generator is a system which is produced by electrolysis of tap water through water purification system and is produced by a special electrolytic cell. The system produce hypochlorous acid (HOCl) with pH (5~6.5), redox potential (ORP value +750mv or more) and available chlorine (50~60mg/L), also produce sodium hydroxide (NaOH) with PH (10~12), redox potential(ORP value -800~900 mv).

View More
Salt Water Sodium Hypochlorite Generator
200g/h Split Type Salt Water Electrolysis Sodium Hypochlorite Generator for Small Drinking Water Plant

The Purevita sodium hypochlorite generator generates a 0.8 % sodium hypochlorite solution through the electrolysis of brine, consuming only water, salt and electricity. By producing hypochlorite on-site and on-demand, the system eliminates concerns associated with transportation and storage of chlorine gas or commercial sodium hypochlorite solutions, making it ideal for any medium to large scale application requiring chlorination.

View More
Commercial Alkaline Water Machine
PH13 100L/H Commercial Alkaline Water Machine for Industrial Cleaning

The alkaline electrolytic ionized water is formed by membrane electrolytic technology, and increases the concentration of hydroxide ions (OH-) (pH 10~12) and oxidation potential (-900 mV) in water. Unlike usual alkaline water, alkaline electrolytic ionized water does not contain synthetic surfactants or chemicals, so it is reliable and safe to use and has a high cleaning, sterilization and deodorization effect. 

View More
Open Channel UV Sterilizer
Low Pressure Open Channel UV System for waste water plant

Purevita UV Sterilization Technology utilizes a specially designed high-intensity, high-efficiency, and long-life C-band 253.6nm ultraviolet light generator to produce powerful UV irradiation for water streams. This UV light destroys the DNA structure of pathogens in water, rendering them inactive and achieving sterilization. The principle of UV sterilization relies on photon energy: shorter wavelengths correspond to higher photon energy, resulting in stronger germicidal efficacy. At 253.6nm, UV light rapidly and efficiently disrupts bacterial DNA, preventing replication and ensuring effective water disinfection.

View More
Hypochlorous Acid Generator
1000ppm PH7 Hypochlorous Acid Generator for Production Line

Hypochlorous acid generator is a system which is produced by electrolysis of tap water through water purification system and is produced by a special electrolytic cell. The system produce hypochlorous acid (HOCl) with pH (5~6.5), redox potential (ORP value +750mv or more) and available chlorine (50~60mg/L), also produce sodium hydroxide (NaOH) with PH (10~12), redox potential(ORP value -800~900 mv).

View More
Polarity Reverse Electrolyzer
200g/h Ruthenium-Iridium coating Polarity Reverse Electrolyzer

The electrolyzer is fed a DC current from the rectifier and electrolyzes the diluted brine into sodium hypochlorite solution. Chlorine evolves at the anode surface, while hydrogen and hydroxide evolves at the cathode surface. The secondary reaction of chlorine, sodium and the hydroxyl ion nets sodium hypochlorite (chlorine bleach) at a 0.8% solution. Below 1%, hypo is classified as a non-hazardous chemical although still a very effective disinfectant. The only by-product, hydrogen, is safely vented into the atmosphere.

View More
  As a sub-brand under Guangzhou jinchuan Environmental Protection Equipment Co., Ltd., we are dedicated to serving the global water treatment market. jinchuan is established in 1993, which is a technology-driven enterprise specializing in electrochemical research. With decades of expertise in catalytic oxidation, electrolysis, disinfection, and the R&D, design, and manufacturing of electrochemical and water treatment equipment, we are one of China's most experienced companies in this f...
Room 814, Building 8, No. 80, Shilian Road (Shiqi Village Section), Shiqi Town, Panyu District, Guangzhou, China
Subscribe to Our Newsletter
Please Read On, Stay Posted, Subscribe, And We Welcome You To Tell Us What You Think.
SIGN UP
Follow Us
facebook pinterest linkedin twitter youtube

Copyright @ Esegen (Guangzhou) Technology Co., Ltd All Rights Reserved. Network Supported

XML Privacy Policy

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

WhatsApp

contact